Ⅰ Standard
Enterprise
standard and equivalent GB, except for combustionproof
property which is up to IEC332.
For
example :combustion proof power cable up to equivalent GB12706-91
combustion
proof control cable up to equivalent GB9330-88
combustion
proof installation wire and cable up to equivalent GB5023-1999 and JB8734-1998
Ⅱ
Application
Addapted
to occasions applying non-combustionproof cables and
occasions with combustionproof requirement.
Ⅲ
Character
a)
Rated voltage(U0/U)from 300/300V to 26/35KV.
b)
Highest permanent work temperature: 70℃、90℃、105℃
c)
Highest workable temperature of conductors
during short circuit(5S): nominal 70℃ 160℃;nominal 90℃ 250℃。
d)
Laying temperature higher than 0℃。
e)
Bending radius up to corresponding non-combustionproof
cable standard.
f)
Combustion proof property is divided
into 3 sorts:A、B、C。(B sort is not recommended)
i.
ZRH type
combustion proof cable is used in common locales requiring
standard of IEC332-3C。
ii.
ZRA type
combustion proof cable is used in sites requiring stricter IEC332-3A standard
iii.
Single cable should achieve the self-quenching
requirement of IEC332-1(2)。Multicore
cable or a bundle of cables should pass IEC332-3, burning within a
certain extent and quenching later by itself.
iv.
Equivalent
to GB12666-90。
Ⅳ
Types
and Sizes
a)
Types
Form 1
Type |
Rated Voltage |
Name |
Application |
ZRA(C)-VV
ZRA(C)-VLV22 |
0.6/1KV |
copper core PVC insulated combustion proof power cable
aluminum core PVC insulated combustion proof power cable |
nuclear power plant 、subway station、communication station、high
edifice、petroleum、metallurgy、power plant、military
facility、tunnel, etc. |
ZRA(C)-YLY
ZRA(C)-YJLV22 |
0.6/1~8.7/10KV |
copper core crosslinked polythene insulation and sheath
combustion proof power cable
aluminum core crosslinked polythene insulation and sheath combustion
proof armored power cable
|
ZRA(C)-KVV
ZRA(C)-KVVR
ZRA(C)-KVVP2 |
450/750V |
copper core PVC insulated combustion proof control cable
copper core PVC insulated combustion proof soft control
cable
copper core PVC insulated metal
shilded armored combustion proof control cable |
ZRA(C)-BV
ZRA(C)-BVV
ZRA(C)-RVB |
450/750V
300/500V
300/300V |
copper core PVC insulated combustion proof cable
copper core PVC insulated combustion proof cable
copper core PVC insulated combustion proof flat soft cable |
fixed or mobile,
laid with power equipment, instruments or meters.
|
ZRA(C)-PYV |
250V |
copper core polythene insulation and sheath combustion proof
power cable |
automatic apparatus of raiways |
ZRA(C)-PUYVR |
250V |
copper core polythene insulation and sheath combustion proof
signal cable |
conveyance in mine tunnel |
ZRA(C)-JYV |
300/500V |
copper core polythene insulation and sheath combustion proof
mine signal soft cable |
computer light current instruments |
Annotation:the obsolescent sort B is
not presented here.
b)
Sizes
Form 2
Type |
Voltage |
cores |
section mm2 |
ZRA(C)-VV ZRA(C)-YLY |
0.6/1~1.8/3KV |
1 |
1.5-800 |
ZRA(C)-VLV22 ZRA(C)-YJLV22 |
10-800 |
ZRA(C)-VV ZRA(C)-YLY |
2 |
1.5-185 |
ZRA(C)-VLV22 ZRA(C)-YJLV22 |
4-185 |
ZRA(C)-VV ZRA(C)-YLY |
3 |
1.5-400 |
ZRA(C)-VL V22 ZRA(C)-YJLV22 |
4-400 |
RA(C)-VV ZRA(C)-YLY
ZRA(C)-VLV22 ZRA(C)-YJLV22 |
3+1
3+2 4+1 |
4-300 |
ZRA(C)-VV ZRA(C)-YLY |
5 |
1.5-300 |
ZRA(C)-VL V22 ZRA(C)-YJLV22 |
4-300 |
ZRA(C)-YLY ZRA(C)-YJLV22
ZRA(C)-YLY ZRA(C)-YJLV22 |
3.6/6~8.7/10KV |
1 |
25-800 |
3 |
25-400 |
ZRA(C)-KVV |
450/750V |
2-14 |
4,6,10 |
2-61 |
0.75,1.0,1.5,2.5 |
ZRA(C)-KVVP2
|
4-14 |
4,6,10 |
6-61 |
0.75,1.0,1.5,2.5 |
ZRA(C)-KVVR |
4-61 |
0.75,1.0,1.5,2.5 |
ZRA(C)-BV |
450/750V |
1 |
1.5-400 |
ZRA(C)-BVV |
300/500V |
1 |
0.75-10 |
2,3,4,5 |
1.5-35 |
ZRA(C)-RVB |
300/300V |
2 |
0.5-2.5 |
ZRA(C)-PYV |
250V |
2-48 |
φ1.0mm |
ZRA(C)-PUYVR |
250V |
4 |
0.5,1.5 |
ZRA(C)-JYV |
300/500V |
2,4,6,19 |
1.0 in twisted group 2,3,4,5,6,10 |
3 |
1.5 in
twisted group 3 |
3 |
1.5 in
wire group 3 |
3 |
2.5 |
Annotation:Other types requiring combustion
proof property but excluded in these samples, should
be recorded in the order as examples in Form 1, and their
applying properties, scope, conditions and sizes please
refer to the representation of corresponding non-combustionproof
types. For convenience, ZRA and ZRC are combined into ZRA(C)in the sample,but you must mark out ZRA or ZRC in
your contract,or else we will regard it as ZRC.
Ⅴ Technical properties refer to corresponding
non-combustionproof cables. |